Which action speeds up refrigerant recovery from a system?

Answer: A. Heating the system appliance.

  1. AHeating the system appliance.✓ Correct
  2. BCooling the system appliance.
  3. CUsing long recovery hoses.
  4. DLeaving the Schrader valve cores in.

Why A is right

Heating the system increases its internal pressure, pushing the refrigerant out faster.